Installation
4-32
L
EDSVS9332P-B EN 3.0
System bus connection (X4)
K1
K1
L3
N
PE
L1
L2
U
V
W
L1 L2
L3
F1
932X - 933X
PE
+UG -UG
PE
Z1
K1
U
V
W
L1 L2 L3
932X - 933X
PE
+UG -UG
PE
Z1
F1
ON
OFF
28
A4
PE
28
A4
K1
RFR
PE
U
V
W
L1 L2 L3
932X - 933X
PE
+UG
-UG
PE
Z1
F1
28
A4
PE
K1
RFR
K1
RFR
GND
HI
LO
GND
HI
LO
RA2
GND
HI LO
RA1
F2 F3 F2 F3 F2 F3
K35.0123
Fig. 4-22 Wiring system bus
RA1, RA2 Bus terminating resistors 120 (included in the accessory kit)
Connection via pluggable screw terminals (double terminals can be used).
Only connect terminals of the same designation.
Features of the system cable:
Total cable length up to 300 m 300 m to 1000 m
Cable type LIYCY2x2x0.5mm
2
twisted-pair with shielding
Pair 1: CAN-LOW (LO) and CAN-HIGH (HI)
Pair 2: 2*GND
CYPIMF2x2x0.5mm
2
twisted-pair with shielding
Pair 1: CAN-LOW (LO) and CAN-HIGH (HI)
Pair 2: 2*GND
Cable resistance χ≤ 40 /km 40 /km
Capacitance per unit
length
130 nF/km 60 nF/km
Connection of the bus terminating resistors:
One resistor 120
each on the first and last bus device.
On the 93XX controller the resistor can be screwed directly under the terminals X4/HI and
X4/ LO.