Starting the engine for driving / switching it off
4.2 Switching off the engine
4 - 22 3 302 633 en Operating Instructions GMK5250L
27.09.2017
4.2.2 With emergency stop switches
Emergency stop switch
Four emergency stop switches are provided
for emergencies:
• Press an emergency stop switch (1), (2)
or (3). The switch latches.
The engine shuts down.
H
If an air intake inhibitor is present, this is then triggered.
H
Do not operate the emergency stop switch to switch the engine off in nor-
mal operation. Only operate the emergency stop switch in an emergency
situation.
Resetting the
emergency stop
switch
You can restart the engine only after you have reset the emergency stop
switch.
• Switch off the ignition.
• Turn the actuated emergency stop switch until it disengages again.
If an air intake inhibitor is present, this must be loosened;
à Releasing the
air intake inhibitor
, p. 4 - 23.
1 On the carrier
2 On the hand-held control
3 In the crane cab

Table of Contents

Other manuals for Manitowoc Grove GMK 5250L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 5250L and is the answer not in the manual?

Manitowoc Grove GMK 5250L Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 5250L
CategoryConstruction Equipment
LanguageEnglish

Related product manuals