Starting/switching off the engine – for crane operation
9.3 Switching off the engine
9 - 10 3 302 633 en Operating Instructions GMK5250L
27.09.2017
9.3.2 In emergencies, with the emergency stop switches
Four emergency stop switches are provided
for emergencies:
• Press an emergency stop switch (1), (2)
or (3). The switch latches.
The engine shuts down.
H
If an air intake inhibitor is present, this is then triggered.
Resetting the
emergency stop
switch
You can restart the engine only after you have reset the emergency stop
switch.
• Switch off the ignition.
• Turn the actuated emergency stop switch until it disengages again.
If an air intake inhibitor is present, this must be loosened;
à Releasing the air intake inhibitor, p. 4 - 23.
G
Risk of overloading if used improperly!
Use the emergency stop switches only in an emergency, i.e. if the crane
functions no longer respond to the control levers.
Stopping crane movements suddenly may cause the truck crane to become
overloaded under unfavourable conditions.
1 On the carrier
2 On the hand-held control
3 In the crane cab

Table of Contents

Other manuals for Manitowoc Grove GMK 5250L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 5250L and is the answer not in the manual?

Manitowoc Grove GMK 5250L Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 5250L
CategoryConstruction Equipment
LanguageEnglish

Related product manuals