Malfunctions during crane operation
14.7 Hydraulic emergency operation as per BGR 159
Operating Instructions GMK5250L 3 302 633 en 14 - 61
27.09.2017
14.7.6 After emergency operation
You must restore the truck crane to its original state after finishing
emergency operation.
Switching off
emergency
operation
Switch off the engine.
Switching over to
crane operation
After every emergency operation
Switch valves 1 to 5 to crane operation; à p. 14 - 55.
Also after lifting/lowering
Switch off continuous operation at the valves Y1105 and Y1104;
à p. 14 - 57.
Also after slewing
Open the valve 6; à p. 14 - 58.
Disconnecting
the hoses
Disconnect the hoses; à p. 14 - 53.
Close all the connections and hoses with the caps.
Remove the transformer.