Crane operation
10.1 Before operating the crane
Operating Instructions GMK5250L 3 302 633 en 10 - 5
27.09.2017
10.1.2 Check the condition of the truck crane
Fuel tank auxiliary
heater
Use the same fuel as for the engine or use EL heating oil for refuelling.
• The display (2) shows the fuel level in the
tank (1).
• Refuel in due time and seal the tank (1) with
the cap.
Visual inspection Walk around the truck crane and look out in particular for leaking oil, fuel or
coolant.
s
S
Danger of fire due to flammable gases!
Turn off the engine and heating systems before refuelling.
G
Danger if the crane cannot be unrigged!
If oil is lost, you may no longer be able to move the crane. Not even in
emergency mode.
O
Risk of environmental damage due to leaking consumables!
Immediately repair or have repaired oil, fuel and coolant leakages.
This prevents oil or fuel from seeping into the ground or polluting waters.