Crane operation
10.7 Working range limiter
Operating Instructions GMK5250L 3 302 633 en 10 - 143
27.09.2017
10.7.6 Shutdown by working range limiter
If a limit value is reached, RCL shutdown will occur. All movements that
would go closer to the limit value will be disabled. Shutdown will remain
active even if you switch off the monitoring function.
The
RCL display also shows an information symbol. You must leave the
shutdown area in order to enable the movement.
If you override the RCL, the shutdown will be overridden and all movements
enabled.
RCL
display
Shutdown point reached
for
Disabled movements
Overall height
–Raising
Extending
Lowering the hoist
Derricking
the lattice extension
Working radius
–Lower
Extending
Lifting the hoist
Derricking the lattice extension
Slewing angle A Slew to the left
Slewing angle B Slew to the right
Rope travel limitation
Lifting
Lifting
Rope travel limitation
Lowering
–Lowering
G
Risk of accidents due to overriding shutdown procedures!
Override RCL only if it is absolutely necessary and you have a clear view of
the hazard area. Bear in mind that, due to the boom bending for example,
the overall height is increased if you set down the load.