Rigging work
11.4 Connecting/disconnecting the hand-held control
11 - 22 3 302 633 en Operating Instructions GMK5250L
27.09.2017
Connecting the hand-held control
Open the cap (2) and pull the bridging
plug (3) out of the socket (1).
Insert the plug (4) into the socket (1) and
secure it with the cap (2).
After approx. 20 seconds, the lamps (5) and
(6) light up – the ignition is now switched on.
There is a malfunction if the lamp (5) does not
light up or if it flashed;
à p. 14 - 21.
Disconnecting the hand-held control
Open the cap (2).
Pull the plug (4) out of the socket (1) – the
lamps (5) and (6) go out.
Insert the bridging plug (3) into the socket (1)
and secure it with the cap (2).
The ignition is switched off, unless it is
switched on at an ignition lock.
G
Danger due to unauthorised use!
Always stow the hand-held control in the driver's cab or in the crane cab
before you leave the crane, and lock the doors.
This way you can prevent unauthorised persons starting the engine.