EasyManuals Logo

Manitowoc Grove GMK 5250L User Manual

Manitowoc Grove GMK 5250L
958 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #730 background imageLoading...
Page #730 background image
Rigging work
11.4 Connecting/disconnecting the hand-held control
11 - 22 3 302 633 en Operating Instructions GMK5250L
27.09.2017
Connecting the hand-held control
• Open the cap (2) and pull the bridging
plug (3) out of the socket (1).
• Insert the plug (4) into the socket (1) and
secure it with the cap (2).
• After approx. 20 seconds, the lamps (5) and
(6) light up – the ignition is now switched on.
There is a malfunction if the lamp (5) does not
light up or if it flashed;
à p. 14 - 21.
Disconnecting the hand-held control
• Open the cap (2).
• Pull the plug (4) out of the socket (1) – the
lamps (5) and (6) go out.
• Insert the bridging plug (3) into the socket (1)
and secure it with the cap (2).
The ignition is switched off, unless it is
switched on at an ignition lock.
G
Danger due to unauthorised use!
Always stow the hand-held control in the driver's cab or in the crane cab
before you leave the crane, and lock the doors.
This way you can prevent unauthorised persons starting the engine.

Table of Contents

Other manuals for Manitowoc Grove GMK 5250L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GMK 5250L and is the answer not in the manual?

Manitowoc Grove GMK 5250L Specifications

General IconGeneral
BrandManitowoc
ModelGrove GMK 5250L
CategoryConstruction Equipment
LanguageEnglish

Related product manuals