Malfunctions during crane operation
14.5 Emergency operations and programs
Operating Instructions GMK5250L 3 302 633 en 14 - 37
27.09.2017
Locking points for the telescopic sections
The telescopic section must not be set down for locking or unlocking it.
The cutout (1) must be clear. That is why you have to extend the telescoping
cylinder further than with a return run.
The following table shows the extended length for locking and unlocking
the telescopic sections.
Table for locking/unlocking the telescopic sections
Telescopic
section
Locking point at
fixed length
Extended length of
telescoping cylinder
in % in mm (in ft)
Telescopic
section
I
0
56
89
100
5
5,282
8,405
9,446
(0.20)
(207.95)
(330.90)
(371.89)
Telescopic
section
II
0
53
89
100
267
5,289
8,706
9,751
10.51
(208.23)
(342.76)
(383.90)
Telescopic
section
III
0
52
89
100
545
5,489
9,011
10,058
(21.46)
(216.10)
(354.76)
(395.98)
Telescopic
section
IV
0
52
92
100
824
5,784
9,600
10,362
(32.44)
(227.71)
(377.52)
(407.95)
Telescopic
section
V
0
47
92
100
1,083
5,539
9,803
10,562
(42.63)
(218.07)
(385.94)
(415.83)
Telescopic
section
VI
0
47
92
100
1,320
5,667
9,832
10,571
(51.97)
(223.11)
(387.09)
(416.18)