Input of the limit 2: In weight, unit same as Max,
transition from small to medium scale interval
Only for [Multiple range] or [Multi-interval]!
View (when CAL-switch is closed)
Max Display only
Scale interval Display only
Dead load at Display only
Max at Display only
Calibrated at Display only
Sensitivity (µV/d) Display only
Param Items as for [Param] (display only)
Setup Setup of the xBPI scale
Calibration Calibration of xBPI scale
Dead load Dead load/preload
Set Set dead load/preload: Accept, ResError, Abort
Delete Clear dead load/preload: Accept, ResError,
Abort
Span
Calibrate with user
weight
Calibrate with auto
weight
Adjust with default
weight
Calibrate with standard weight.
Adjust with internal
weight
Calibrate with internal weight.
Linearity Setting linearity.
Default Resetting the Device to the Factory Settings:
Accept, ResError, Abort
User User defined settings: Accept, ResError, Abort
Configuration Configuration of the scale
Weighing parameters Weighing parameters
Ambient conditions Select environmental conditions: Very stable,
stable, unstable, very unstable
Application filter Select application filter: Final readout, Filling
mode, Low filtering, w/o filtering
Standstill range Select standstill range: 0.25 igit, 0.5 digit,
1 digit, 2 digit, 4 digit, 8 digit
Stability symb. delay Select Stability delay: no delay, short delay,
average delay, long delay
Tare parameter Select taring: at any time, not until stable
Auto zero function Auto-Zero: auto zero on, auto zero off
Adjustment function Adj. sequence: ext.adj.w.fact.wt.,
ext.adj.w.user.wt., ext.adj.w.pres.wt., internal
adjust, ext.lin.w.fact.wt., ext.lin.w.user.wt.,
confirm preload, delete preload, adjust
disabled
Confirming adjust. Confirm calibration: manual, automatically
Zero range Zero point range: 1% of max load = 1%/Max.
load, 2% of max load = 2%/Max. load, 5% of
7.13.7.2 "xBPI scale" weighing point
Calibrate with user-defined weight.
Calibrate with automatic weight detection.
X3 Process Indicator PR 5410 7 Getting started
EN-156 Minebea Intec

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Minebea Intec X3 and is the answer not in the manual?

Minebea Intec X3 Specifications

General IconGeneral
BrandMinebea Intec
ModelX3
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals