¾ 5-4 ¾
Feature Programming
To program an option:
1. Dial program number (1 - 99).
2. Dial *.
3. Enter the required information as shown in programming entry. (under each program
description).
4. Dial *.
5. Repeat steps 3 - 4 if there is more than one entry. (extension , trunks, etc.)
6. Dial # to exit the current program number.
Example of Programming
Program #01 Each Line Assignment 1 (Method)
Dial Display Meaning
1 PROGRAMMING
01
Programming No. 1
*
LINE ASSIGNMENT1
01-00
4 LINE ASSIGNMENT1
01-04
Line No. 4
*
LINE ASSIGNMENT1
01-04-10100
3
LINE ASSIGNMENT1
01-04-01003
Type of line
(3: Behind PBX)
1 LINE ASSIGNMENT1
01-04-10031
Dial mode
(1: DTMF)
4 LINE ASSIGNMENT1
01-04-00314
Queuing group
(4: Group 4)
1 LINE ASSIGNMENT1
01-04-03141
PBX night mode
(1: enable)
0 LINE ASSIGNMENT1
01-04-31410
Polarity Reverse Detection
(0: Disable)
*
LINE ASSIGNMENT1
01-05-10100
Ready for Line No. 5
#
PROGRAMMING
00
Exit this item.
End (At item number input condition)
1. Press "HOLD" key.
Note 1: When Protect Switch on the NX7E-308M/408M-A1 or NX7E-24CPU-B1 Unit is set to initial
side or error Data are programmed, you cannot exit the programming mode.
Note 2: If you enter programs which are not described in this manual e.g. No. 65 to 73 for TX-Z
1232/2464, exit them without changing data. These programs are for other options.