¾
3-1-11
¾
24 V DC Battery Supply
Connecting external battery with main equipment, the TX-Z
308 system can start even in the case of a
power supply failure. If the external battery has been connected in advance, the main equipment
automatically switches to battery power when a power failure occurs.
Required Battery: Yuasa NP2.6-12 (rated at 12 volts, 2.6 amp-hours) ´ 2 piece
Note:
A battery storage box (DX2E-32i/NX7E Battery Box) must be required to accommodate above
batteries.
To install batteries in the battery box:
1. Loosen the screw and remove the front cover of battery box.
2. Insert one pair of batteries.
3. Secure batteries with tie-wraps attached.
4. Connect attached wires to the battery terminals correctly. (See the following illustration)
5. Put the cover back and secure the screws.
To connect the battery box with main equipment:
1. Disconnect the AC cord of main equipment from an AC outlet.
2. Loosen the screw and remove the front cover of main equipment.
3. Loosen the screw and remove the upper housing of main equipment.
4. Connect the battery box and the main equipment (insert plug into connector made CN201) using a
cable attached with battery box.
Battery Box
Blue
Orange
Red
155 mm
280 mm
CN201
Battery cable