¾ 7-1-4 ¾
Installation of 3CIDU-A1 Unit (TX-Z 308)
6. For the wiring between 3CIDU-A1 unit and 308M-A1 Unit, use some tool to knock-out panel
as the illustration and through the upper housing to connect to the COCN connector on the
308M-A1 unit.
7. After wiring, put the housing and cover back and secure the screws.
8. Plug the AC cord into an AC outlet.
Removing the knock-out
panel
Through upper housing to
connect to COCN connector
on the 308M-A1 unit.
IMPORTANT!!: After all the connections are completed, plug the AC cord.