— 9-12 —
BS: Fieldbus Status
Monitors the status of communication status of the fieldbus. This function is only available for
the EDC Driver Unit corresponding to CC-Link.
Category Monitor
Format
BS
The following show an example of the readout.
Fig 9-2: Example of the monitor BS
Status of fieldbus
:
BS/RP
BS
FEDCBA9876543210
0000000000000000
_
Guide code
0: OFF
1: ON
Table 9-5: Readout of the monitor BS
Guidi
ng
code
F E D C B A 9 8 7 6 5 4 3 2 1 0
Output signal
Error in change of setting
station number
Error in change of baud rate
setting switch
Error in checking of error
occurrence
Error in SW of baud rate.
Error in checking of
Communicating condition
Error in CPU.
CPU STOP error
Error in number of RY data.
Error in time over setting.
Error in time over.
Error in maker code.
Error in setting of machine
code + version setting
Busy communicating
Error in number of slave
station
Error in baud rate setting
Error in station number setting
P BW: Busy Width
Specifies the minimum signal holding time of the BUSY output (In-operation).
Refer to “7.2.5. Output BUSY(In-operation)” for details.
Category Parameter
Format
BW data
Data range 0.0 to 10 000.0 [ms]
Shipping set 0.0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NSK Megatorque PS Series and is the answer not in the manual?

NSK Megatorque PS Series Specifications

General IconGeneral
BrandNSK
ModelMegatorque PS Series
CategoryEngine
LanguageEnglish

Related product manuals