— 9-28 —
FTJO: Function TJO
This is to monitor the state of the output JO (Thermal loading, under).
◊ Refer to “7.3.1.5. Monitor for Individual Function” for details.
For the monitored state, the parameters ST (Stability timer) and GC (Output logic) in the
command PO (Edit output port) are not applied.
Category Monitor
Format
FTJO
0
: Not detected
Data range
1
: Thermal loading is less or equal to the threshold.
FTJU: Function TJU
This is to monitor the state of the output TJU (Tell thermal, under).
◊ Refer to “7.3.1.5. Monitor for Individual Function” for details.
For the monitored state, the parameters ST (Stability timer) and GC (Output logic) in the
command PO (Edit output port) are not applied.
Category Monitor
Format
FTJU
0
: Not detected
Data range
1
: Thermal loading is less or equal to the threshold.
FTTO: Function TTO
This is to monitor the state of the output TTO (Tell torque command, over).
◊ Refer to “7.3.1.5. Monitor for Individual Function” for details.
For the monitored state, the parameters ST (Stability timer) and GC (Output logic) in the
command PO (Edit output port) are not applied.
Category Monitor
Format
FTTO
0
: Not detected
Data range
1
: Torque command is greater or equals to the threshold.