— 9-50 —
P MXY: Monitor Offset, Secondary
The parameter MXY sets the offset of a monitor output specified by the parameter MX.
Refer to “7.4.2. Customization of Monitor Data” for details.
Category Parameter
Format
MXY data
Data range
Depends on the setting of parameter
MX.
Shipping set 0.000
MY: Motor Cycle Stop
The command MY causes the cycle stop of currently executing programmed operation.
The program processing stops at completion of program line currently executed
If the Motor is moving, it stops at its completion of the operation.
Category Command
Format
MY
P NA: Near A
The parameter sets a proximity distance to activate the output NEARA (Target proximity A).
Refer to “7.2.7. Target proximity: NEARA and NEARB” for details.
In a positioning operation, the output NEARA closes when the Motor reaches to the point short
from the target position set by the parameter NA in units of pulse.
Category Parameter
Format
NA data
Data range
0 to 2 62 144 000
[pulse]
Shipping set 0
P NB: Near B
The parameter sets a proximity distance to activate the output NEARB (Target proximity A).
Refer to “7.2.7. Target Proximity: NEARA and NEARB” for details.
In a positioning operation, the output NEARB closes when the Motor reaches to the point short
from the target position set by the parameter NB in units of pulse.
Category Parameter
Format
NB data
Data range
0 to 2 62 144 000
[pulse]
Shipping set 0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NSK Megatorque PS Series and is the answer not in the manual?

NSK Megatorque PS Series Specifications

General IconGeneral
BrandNSK
ModelMegatorque PS Series
CategoryEngine
LanguageEnglish

Related product manuals