— 9-52 —
P OE: Sequence Option Edit
This parameter controls the program processing sequence between program channels.
For an example, the parameter OE enables following program processing:
• Continual execution of channel programs with consecutive channel number
• Every input of the input RUN executes the program of the following channel
number.
Refer to “6.3.2.4. Program Sequence” for details.
Category Parameter
Format
OE data
0
: Completes program processing after execution of current channel.
1
: After completion of the current program channel, executes the program of
the following channel number. (Ignores the input RG.)
Data range
2
: Continually executes the program channel with the following number.
Shipping set 0
Ì
OP: Compulsion Output
The command OP forcibly changes the state of the output ports PO0 to PO7 of the connector
CN2 (Control Input/Output connector) and the field bus (CC-Link) outputs.
Refer to “8.1.3.4. Forcible Change in Setting Output Port Function” for details.
It can be used for checking interface with the master controller.
Category Command
Format
OP d
7
d
6
d
5
d
4
d
3
d
2
d
1
d
0
0
: Open
1
: Closed
Data range (d
n
)
X
: No change in the state of outputs
The data d
7
to d
0
correspond respectively to the output ports PO7 to PO0.
Ì
P OS: Origin Setting Mode
The parameter OS specifies the operation mode of Home Return.
Refer to “8.8. Home Return” for details.
Category Parameter
Format
OS
1
: Sets the home position to the point passing the ON area of home sensor.
3
: Sets the home position to the detecting point of the first øZ signal after
passing the home sensor ON area.
4
: Sets the home position to the detecting point of the first øZ signal after
entering the home sensor ON area.
5
: Sets the home position to the point entering to the home sensor ON area.
6
: Sets the home position to the current position. The Motor does not move.
Data range
7
: Sets the home position to the detecting point of øZ signal when returning
in the direction to the signal after entered the ON area of the limit sensor.
Shipping set 6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NSK Megatorque PS Series and is the answer not in the manual?

NSK Megatorque PS Series Specifications

General IconGeneral
BrandNSK
ModelMegatorque PS Series
CategoryEngine
LanguageEnglish

Related product manuals