VTrak E-Class Product Manual
326
Host-interface controller
has encountered a
system error
A VTrak system error occurred. If this message
appears repeatedly, contact Technical Support. See
page 355.
Host-interface controller
has encountered a fatal
error
Restart the VTrak. See page 119 or page 245. If this
message appears repeatedly, contact Technical
Support. See page 355.
Host-interface controller
settings have changed
Result of user action. Normal.
Logical Drive
Logical drive initialization
has started
Result of user action. Normal.
Logical drive initialization
has completed
Logical drive is ready to use. Normal.
Logical drive initialization
has paused
Initialization paused because of user intervention,
schedule or a higher priority background activity.
Logical drive initialization
has resumed
Initialization has resumed again after a pause.
Logical drive initialization
has stopped
Initialization stopped because of user intervention,
schedule or the logical drive was deleted or went
critical or offline.
Logical drive initialization
marks the logical drive
offline
Initialization failure due to a failed disk drive. Replace
the disk drive, delete and recreate the logical drive.
See page 147 or page 200.
Logical drive initialization
is aborted due to an
internal error.
System resources are low. Reduce system load or
restart the VTrak. See page 119 or page 245.
Logical drive initialization
is queued
Initialization has been set manually or by schedule.
A new logical drive has
been created
Result of user action. Normal.
Logical drive has been
deleted
Result of user action. Normal.
Logical drive has been
placed online
The physical drives of the array are restored to online
status.
Logical drive has been
placed online. Possible
data loss
One or more physical drives in the array went offline.
See page 336.
Reported Event Corrective Action