Operation
Diesel engine
Water content
The maximum permissible water content in diesel fuel is 200 mg/kg.
6.7.1 Start/shut down diesel engine
If the drive pedal is not in resting position during starting, then for safety reasons, trac-
tion drive is blocked. The block remains until the drive pedal is completely released
and pressed again.
ATTENTION
Risk of machine damage.
Use of chemical starting aids (e.g. Startpilot etc.) is expressly prohibited, as it may
lead to injuries and to machine damage.
The ignition lock has three switching positions:
Position 0: Shut down diesel engine/ignition off – the key may be removed
Position I: Ignition on, the diesel engine is ready for start
Position II: Start diesel engine (not connected)
Use the START key to start the diesel engine and the STOP key or ignition
lock to shut it down.
ADVICE
After each start of the engine, the fan of the cooling system is automatically reversed
for a short time. This frees the cooling system of loose dirt (leaves, etc.).
CAUTION
It is necessary for the safe operation of the control units that the ignition is switched
off at least once every 24 hours (position 0). Wait until the green LED on the colour
terminal goes off before switching the machine on again. Only then the machine is
considered to be switched off completely.
ADVICE
To start the diesel engine press and hold the START key (19) for at least 3 sec.. If the
START key is pressed too briefly, a note appears on the terminal.