Maintenance and Service
Pump distributor gears (PDG)
Lubrication pump distributor gears failed!
Start diesel engine and watch the R-Touch. The warning icon should disappear
from the R-Touch within 10 seconds.
If the warning icon does not disappear in 10 sec., shut down the diesel engine
immediately and bleed the transmission.
Let the diesel engine run for a minute, then shut it off.
Wait at least 10 minutes, then check the oil level again – as described above, in
case of need, correct oil level.
Bleeding the transmission
(7) Pressure filter bowl
(8) PDG control unit
(9) MP port plug
Place an oil catch basin under the control block (8).
Remove the plug at the MP port (9).
Close the engine compartment cover and fold up the pump cover behind the lad-
der.
Observe the MP port (9) on the control unit (8) through the opening.
Have another reliable and trained person start the diesel engine and let it run (max-
imum 15 seconds) until the gear oil comes out of the opening in the control unit (8)
without bubbles.
Screw in the plug as soon as the oil is bubble-free and tighten it with a torque of
16 Nm. If oil does not come out within 15 seconds, screw in the plug again and
contact customer service.
Wait at least 10 minutes and check the oil level again as described above.
Fill in some oil after in necessary.