[Enable]
Enable or disable the functions for FTP.
[FTP Timeout]
Set the connection timeout period between the product's FTP server and clients.
Specify the maximum number of seconds that the product's FTP server will allow clients to stay
connected without receiving any data on either the control or data connection.
The setting range is from 10 to 3600 seconds.
[SNMP]
Set the functions for SNMP.
The SNMP function enables you to monitor and manage a UDP/IP based network.
The setting items are as follows:
[sysContact]
Set the contact information.
You can enter 0 to 255 characters. Alphabets, numbers and symbols can be used.
[sysName]
Set the name information.
You can enter 0 to 255 characters. Alphabets, numbers and symbols can be used.
[sysLocation]
Set the location information.
You can enter 0 to 255 characters. Alphabets, numbers and symbols can be used.
[prtMarkerCounterUnit]
Set the unit to use for reporting counter values for subunits.
The options are as follows:
impressions
Report the number of printed labels.
meters
Report the length of printed labels in meters.
[Agent]
Set the Agent function.
The setting items are as follows:
[Enable]
Enable or disable the functions for Agent.
[Read-Only]
Set the read-only function.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SATO CT4-LX and is the answer not in the manual?

SATO CT4-LX Specifications

General IconGeneral
Print MethodThermal Transfer / Direct Thermal
Print Resolution203 dpi
Max Print Width4.09 inches (104 mm)
Media TypeRoll, Fan-fold
Media Thickness0.0025 to 0.008 inches (0.0635 to 0.2032 mm)
Ribbon Width0.98 inches (25 mm) to 4.09 inches (104 mm)
Ribbon Length984 feet
ConnectivityUSB, Ethernet, Bluetooth
Supported Barcode TypesPDF417, QR Code
Power Requirements100-240 VAC, 50/60 Hz