Engineer programming via the browser
Installation & Configuration Manual
Time (in seconds) in which ‘All okay’ must be confirmed before alarm is
raised. (Range 1 – 999 seconds)
Select the event type to be sent when the ‘All okay’ timer expires.
Options are Panic (Silent), Panic and Duress.
RF Output
Enter the number of seconds that the RF Output will remain on
for.
0 seconds will toggle the output on and off.
The other Miscellaneous options are described in Entry/Exit [âž™ 239] for SPC Pro
Fire Exit Route
Select the doors which will open when fire
occurs in this area. This option does not
display in domestic mode.
Area Triggers
The Triggers section is only displayed if triggers have been defined previously.
(See section on Triggers)
Click on the Edit button to add, edit or delete trigger conditions for the area. The
following page is displayed:
Configure the trigger for the area using the following parameters:
Select a trigger from the drop down list.
The trigger can activate from either the positive or negative