Engineer programming via the browser
Configuring Communications
Installation & Configuration Manual
Report IP Network Polling Up/Down events.
Select specific areas to which above events apply.
Editing EDP settings
1. Select Communications > Reporting > EDP > Settings.
The following window will be displayed.
2. Configure the fields as described in the table below.
Tick this checkbox to enable EDP operation on the system.
Enter a numeric identifier that is used by the EDP Receiver to identify the
panel uniquely.
Select the IP port for receiving IP packets. Default is 50000.
Enter the maximum number of bytes in an EDP packet for transmission.
Enter the timeout period (in seconds) between retransmissions of
unacknowledged events.
Enter the maximum number or event retransmissions allowed by the system.
Enter the maximum number of failed dial attempts accepted by the system
before the modem is locked out (prevented from making further attempts to
dial). The lockout period is defined in the option Dial Lockout.