EasyManua.ls Logo

Vanderbilt SPC53 Series - Page 300

Vanderbilt SPC53 Series
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
Engineer programming via the browser
Configuring Communications
300
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
Check any of the following boxes if you want to initiate a remote call to an EDP
Receiver to notify it of the particular event.
Alarms
Alarms are activated.
Alarm Restores
System alarms are restored.
Confirmed Alarms
Alarms confirmed by multiple zones
Alarm Abort
Alarm Abort events. Alarms are aborted after a valid user code is entered
via the keypad after a confirmed or unconfirmed alarm,
Faults
Faults and tampers are activated.
Fault Restores
Fault or tamper alarms are restored.
Zone state
Report all zone input state changes.
Settings
System is Set and Unset.
Early/Late
Unscheduled setting and unsetting of the system.
Inhibits
Inhibit and isolate operations are performed on the system.
Door Events
Door events are activated. Only works with SIA protocol.
Other
All other types of events are detected on the system.
Other (Non standard)
Non supported SIA codes used with SPC COM XT including Camera
Online/Offline events.

Table of Contents

Related product manuals