Phaser 790/DocuColor 2006
033-221/222/223/224/225/226/226/227/228, 033-330/
Initial Issue
Status Indicator RAPs
033-221/222/223/224/225/226/226/227/228 IOT/IIT
Communication RAP
033-221: The Control Logic detects a 1394 PWB communication time-out.
033-222: The Control Logic detects a 1394 PWB communication error.
033-223: The Control Logic detects a 1394 PWB connection time-out.
033-224: The Control Logic detects a 1394 PWB reconnection time-out.
033-225: The Control Logic detects a 1394 PWB reconnection failure.
033-226: The Control Logic detects an Async transaction time-out.
033-227: The Control Logic detects an Async transaction retry error.
033-228: The Control Logic detects a 1394 PWB link chip error.
Initial Actions
Check the cables and connections between the IIT and the IOT. Ensure that the cables are
secure.
Exit, then re-enter Copy Mode. If this does not resolve the problem, switch the power off then
on. Verify that the problem still exists.
Procedure
Remove the Right Cover (REP 14.9). Verify that the 1394 PWB is correctly installed. If the
PWB is installed correctly and the problem still exists, replace the 1394 PWB (PL 12.1). If the
problem continues, replace the ICM Main PWB (PL 16.2).
033-330/331/332 Software Error RAP
An XPro software error was detected.
Procedure
Replace the IPS PWB (PL 16.2). If the problem remains, replace the ICM Main PWB (PL 16.2).