10/00
4-90
Phaser 790/DocuColor 2006
REP 8.43
Initial Issue
Repairs and Adjustments
REP 8.43 Top Exit Sensor
Parts List on PL 9.2
Removal
WARNING
To avoid personal injury or shock, do not perform repair activities with the power switch
on or electrical power applied to the machine.
1. Switch off the machine power and disconnect the machine Power Cord.
2. Remove the Exit Transport Assembly. (REP 8.40)
3. Remove the Top Exit Sensor (Figure 1).
Figure 1 Removing the Top Exit Sensor
Replacement
1. Perform the removal procedure in reverse.
1
Disconnect the
connector
2
Release the locking tabs
and remove the Top Exit
Sensor