1.2 Verifying the Drive Model and Nameplate
24 YASKAWA SIEPC71061705H GA700 Series Technical Manual
Table 1.1 Model Number Details
No. Description
1 Drive
2 Product series
3 Region code
• A: Japan
• B: China
• C: Europe
• D: India
• K: Korea
• T: Asia (Singapore and Taiwan)
• U: Americas
4 Input power supply voltage
• 2: Three-Phase AC 200 V Class
• 4: Three-Phase AC 400 V Class
5 Rated output current
Note:
Refer to the tables for the rated output current by model.
6
EMC noise filter
• A: No internal EMC filter
• B: Internal category C3 EMC filter
7 Protection design
• B: IP20
8 Environmental specification (Reserved)
9 Design revision order
10 Control circuit terminal board (Reserved)
11 Option (connector CN5-A) (Reserved)
12 Option (connector CN5-B) (Reserved)
13 Option (connector CN5-C) (Reserved)
14 Keypad (Reserved)
15 Special applications (Reserved)
■ Rated Output Current
Table 1.2 to Table 1.4 give the rated output current values.
Note:
• These output current values are applicable for drives that operate at standard specifications.
• Derate the current in applications that:
–Increase the carrier frequency
–Have high ambient temperature
–Install drives side-by-side.
• Use C6-01 [Normal / Heavy Duty Selection] to select Normal Duty rating (ND) or Heavy Duty rating (HD).
Table 1.2 Three-Phase AC 200 V Class
Model
Heavy Duty Rating (HD)
[C6-01 = 0]
(Default)
Normal Duty Rating (ND)
[C6-01 = 1]
Maximum Applicable Motor
Output
kW
Rated Output Current
A
Maximum Applicable Motor
Output
kW
Rated Output Current
A
2004 0.55 3.2 0.75 3.5
2006 0.75 5 1.1 6
2010 1.5 8 2.2 9.6
2012 2.2 11 3 12.2
2018 3 14 4 17.5
2021 4 17.5 5.5 21
2030 5.5 25 7.5 30
2042 7.5 33 11 42