10.9 Peripheral Devices and Options
472 YASKAWA SIEPC71061705H GA700 Series Technical Manual
Name Model Intended Use Document No.
PROFIBUS-DP SI-P3
This option uses the host controller over PROFIBUS-DP communication to:
Operate and stop the drive
Set and view parameters
Monitor output frequency, output current, and other statuses
TOBPC73060082
SIJPC73060082
CC-Link SI-C3
This option uses the host controller over CC-Link communication to:
Operate and stop the drive
Set and view parameters
Monitor output frequency, output current, and other statuses
TOBPC73060083
SIJPC73060083
DeviceNet SI-N3
This option uses the host controller over DeviceNet communication to:
Operate and stop the drive
Set and view parameters
Monitor output frequency, output current, and other statuses
Note:
The drive is compatible with option software versions 1114 and later.
TOBPC73060084
SIJPC73060084
CANopen SI-S3
This option uses the host controller over CANopen communication to:
Operate and stop the drive
Set and view parameters
Monitor output frequency, output current, and other statuses
TOBPC73060085
SIJPC73060085
MECHATROLINK-II SI-T3
This option uses the host controller over MECHATROLINK-II communication
to:
Operate and stop the drive
Set and view parameters
Monitor output frequency, output current, and other statuses
Note:
The drive is compatible with option software versions 6108 and later.
TOBPC73060086
SIJPC73060086
MECHATROLINK-III SI-ET3
This option uses the host controller over MECHATROLINK-III
communication to:
Operate and stop the drive
Set and view parameters
Monitor output frequency, output current, and other statuses
Note:
The drive is compatible with option software versions 6202 and later.
TOBPC73060088
SIJPC73060088
EtherNet/IP SI-EN3
This option uses the host controller over EtherNet/IP communication to:
Operate and stop the drive
Set and view parameters
Monitor output frequency, output current, and other statuses
TOBPC73060092
SIEPC73060092
Modbus TCP/IP SI-EM3
This option uses the host controller over Modbus TCP/IP communication to:
Operate and stop the drive
Set and view parameters
Monitor output frequency, output current, and other statuses
TOBPC73060091
SIEPC73060091
LONWORKS SI-W3
This option uses the host controller over LONWORKS communication to:
Operate and stop the drive
Set and view parameters
Monitor output frequency, output current, and other statuses
TOBPC73060093
SIEPC73060093
PROFINET SI-EP3
This option uses the host controller over PROFINET communication to:
Operate and stop the drive
Set and view parameters
Monitor output frequency, output current, and other statuses
TOBPC73060089
SIJPC73060089
EtherCAT SI-ES3
This option uses the host controller over EtherCAT communication to:
Operate and stop the drive
Set and view parameters
Monitor output frequency, output current, and other statuses
TOBPC73060096
SIJPC73060096
Table 10.77 Types of Option and Connectors
Option Available Connector Ports Number of Options Permitted
PG-B3, PG-X3 CN5-C (CN5-B) 2
*1
PG-F3
*2
, PG-RT3
*2
CN5-C 1
AO-A3, DO-A3 CN5-A, B, and C 1
AI-A3
*3
, DI-A3
*3
, SI-C3, SI-EL3, SI-EM3, SI-EN3, SI-EP3, SI-ES3, SI-ET3, SI-N3,
SI-P3, SI-S3, SI-T3, SI-W3
CN5-A 1
*1 To connect only one encoder options, use the CN5-C connector. To connect two encoder options, use the CN5-C and CN5-B
connectors.
*2 If you use the motor switching function, you cannot use this option.
*3 To use AI-A3 and DI-A3 input statuses as monitors, connect the option cards to one of CN5-A, CN5-B, or CN5-C. Use U1-21, U1-
22, and U1-23 to confirm the AI-A3 input status. Use U1-17 to confirm the DI-A3 input status.