Parameter List
11
11.20 Parameters Changed by E1-03 [V/f Pattern Selection]
YASKAWA SIEPC71061705H GA700 Series Technical Manual 601
Table 11.3 Parameters Changed by E1-03 (2257 - 2415 and 4140 - 4675)
No. E1-03 E1-04 E1-05
*1
E1-06 E1-07 E1-08
*1
E1-09 E1-10
*1
Unit - Hz V Hz Hz V Hz V
Setting Value
0 50.0 200.0 50.0 2.5 12.0 1.3 6.0
1 60.0 200.0 60.0 3.0 12.0 1.5 6.0
2 60.0 200.0 50.0 3.0 12.0 1.5 6.0
3 72.0 200.0 60.0 3.0 12.0 1.5 6.0
4 50.0 200.0 50.0 25.0 35.0 1.3 5.0
5 50.0 200.0 50.0 25.0 50.0 1.3 6.0
6 60.0 200.0 60.0 30.0 35.0 1.5 5.0
7 60.0 200.0 60.0 30.0 50.0 1.5 6.0
8 50.0 200.0 50.0 2.5 15.0 1.3 7.0
9 50.0 200.0 50.0 2.5 20.0 1.3 9.0
A 60.0 200.0 60.0 3.0 15.0 1.5 7.0
B 60.0 200.0 60.0 3.0 20.0 1.5 11.0
C 90.0 200.0 60.0 3.0 12.0 1.5 6.0
D 120.0 200.0 60.0 3.0 12.0 1.5 6.0
E 180.0 200.0 60.0 3.0 12.0 1.5 6.0
F 50.0
*2
200.0
*2
50.0
*2
2.5
*2
12.0
*2
1.3
*2
6.0
*2
Control Method
Selection
(A1-02 Setting)
OLV (2) 50.0 200.0 50.0 3.0 13.2 0.5 2.4
CLV (3) 50.0 200.0 50.0 0.0 0.0 0.0 0.0
OLV/PM (5)
*3
*3 *3
- -
*3
-
AOLV/PM (6)
*3 *3 *3
- -
*3
-
CLV/PM (7)
*3 *3 *3
- - 0.0 -
*1 This is the value for 200 V class drives. Double the value for 400 V class drives.
*2 These values are the default settings for E1-04 to E1-10 and E3-04 to E3-10 [V/f Pattern for Motor 2]. These settings are the same as
those for the V/f pattern when E1-03 = 1 [Const Trq, 60Hz base, 60Hz max].
*3 The default setting varies depending on the setting of E5-01 [PM Motor Code Selection].