Parameter List
11
11.21 Defaults by Drive Model and Duty Rating ND/HD
YASKAWA SIEPC71061705H GA700 Series Technical Manual 615
No.
*1
Name Unit Default
- Drive Model - 4168 4208 4250 4296
C6-01
Normal /
Heavy Duty
Selection
-
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04
Drive Model
(KVA)
Selection
Hex. A5 A6 A7 A8
E2-11
(E4-11)
Motor Rated
Power
kW 75 90 90 110 110 150 150 185
b3-08
Speed
Estimation
ACR P Gain
- 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8
b3-26
Direction
Determination
Level
- 1000 1000 1000 1000 1000 1000 1000 1000
b8-03
Energy Saving
Filter Time
s 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00
b8-04
Energy Saving
Coefficient
Value
- 46.2 38.91 38.91 36.23 36.23 32.79 32.79 30.13
C5-17
(C5-37)
Motor Inertia kgm
2
0.90 1.10 1.10 1.90 1.90 2.10 2.10 3.30
C6-02
Carrier
Frequency
Selection
- 1 7 1 7 1 7 1 7
E2-01
(E4-01)
Motor Rated
Current (FLA)
A 130 156 156 190 190 223 223 270
E2-02
(E4-02)
Motor Rated
Slip
Hz 1.39 1.4 1.4 1.4 1.4 1.38 1.38 1.35
E2-03
(E4-03)
Motor No-
Load Current
A 36 40 40 49 49 58 58 70
E2-05
(E4-05)
Motor Line-
to-Line
Resistance
Ω 0.092 0.056 0.056 0.046 0.046 0.035 0.035 0.029
E2-06
(E4-06)
Motor
Leakage
Inductance
% 20 20 20 20 20 20 20 20
E2-10
(E4-10)
Motor Iron
Loss
W 1600 1760 1760 2150 2150 2350 2350 2850
E5-01
PM Motor
Code
Selection
- 1246 1246 1247 1247 1248 1248 1249 1249
L2-02
Power Loss
Ride Through
Time
s 2 2 2 2 2 2 2 2
L2-03
Minimum
Baseblock
Time
s 1.3 1.5 1.5 1.7 1.7 1.7 1.7 1.8
L2-04
Powerloss V/f
Recovery
Ramp Time
s 1 1 1 1 1 1 1 1
L2-05
Undervoltage
Detection Lvl
(Uv1)
- 380 380 380 380 380 380 380 380
L3-24
Motor Accel
Time @ Rated
Torque
s 0.533 0.592 0.592 0.646 0.646 0.673 0.673 0.777
L8-02
Overheat
Alarm Level
°C 110 110 105 105 120 120 120 120
L8-09
Output
Ground Fault
Detection
- 1 1 1 1 1 1 1 1
L8-38
Carrier
Frequency
Reduction
- 2 2 2 2 2 2 2 2
n1-01
Hunting
Prevention
Selection
- 2 2 2 2 2 2 2 2
n1-03
Hunting
Prevention
Time Constant
ms 30 30 30 30 30 30 30 30

Table of Contents