12.7 F: Options
792 YASKAWA SIEPC71061705H GA700 Series Technical Manual
F6-68 to F6-71: Dynamic In Assembly 159 Param 1 to 4
No.
(Hex.)
Name Description
Default
(Range)
F6-68 to F6-71
(03E3, 03E4,
03C7, and 03C8)
Dynamic In Assembly 159
Param 1 to 4
Sets Configurable Inputs 1 to 4 read from the MEMOBUS register.
0000H
(0000H - FFFFH)
F6-72: PowerLink Node Address
No.
(Hex.)
Name Description
Default
(Range)
F6-72
(081B)
PowerLink Node Address
Sets the node ID for PowerLink communication.
0
(0 - 255)
F7-01: IP Address 1
No.
(Hex.)
Name Description
Default
(Range)
F7-01
(03E5)
IP Address 1
Sets the first octet of the IP Address for the device that is connecting to the network. Restart the
drive after you change this parameter.
192
(0 - 255)
Note:
When F7-13 = 0 [Address Mode at Startup = Static]:
Use parameters F7-01 to F7-04 [IP Address 1 to 4] to set the IP Address. Be sure to set a different IP address for each drive on the
network.
Also set parameters F7-05 to F7-12 [Subnet Mask 1 to 4, Gateway Address 1 to 4].
F7-02: IP Address 2
No.
(Hex.)
Name Description
Default
(Range)
F7-02
(03E6)
IP Address 2
Sets the second octet of the IP Address for the device that is connecting to the network. Restart the
drive after you change this parameter.
168
(0 - 255)
Note:
When F7-13 = 0 [Address Mode at Startup = Static]:
Use parameters F7-01 to F7-04 [IP Address 1 to 4] to set the IP Address. Be sure to set a different IP address for each drive on the
network.
Also set parameters F7-05 to F7-12 [Subnet Mask 1 to 4, Gateway Address 1 to 4].
F7-03: IP Address 3
No.
(Hex.)
Name Description
Default
(Range)
F7-03
(03E7)
IP Address 3
Sets the third octet of the IP Address for the device that is connecting to the network. Restart the
drive after you change this parameter.
1
(0 - 255)
Note:
When F7-13 = 0 [Address Mode at Startup = Static]:
Use parameters F7-01 to F7-04 [IP Address 1 to 4] to set the IP Address. Be sure to set a different IP address for each drive on the
network.
Also set parameters F7-05 to F7-12 [Subnet Mask 1 to 4, Gateway Address 1 to 4].
F7-04: IP Address 4
No.
(Hex.)
Name Description
Default
(Range)
F7-04
(03E8)
IP Address 4
Sets the fourth octet of the IP Address for the device that is connecting to the network. Restart the
drive after you change this parameter.
20
(0 - 255)
Note:
When F7-13 = 0 [Address Mode at Startup = Static]:
Use parameters F7-01 to F7-04 [IP Address 1 to 4] to set the IP Address. Be sure to set a different IP address for each drive on the
network.
Also set parameters F7-05 to F7-12 [Subnet Mask 1 to 4, Gateway Address 1 to 4].
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV

Table of Contents