Parameter Details
12
12.8 H: Terminal Functions
YASKAWA SIEPC71061705H GA700 Series Technical Manual 835
10: Alarm
Setting Value Function Description
10 Alarm
The terminal activates when the drive detects a minor fault.
11: Fault Reset Command Active
Setting Value Function Description
11 Fault Reset Command
Active
The terminal activates when the drive receives the Reset command from the control circuit terminal, serial communications, or
the communication option.
12: Timer Output
Setting Value Function Description
12 Timer Output
Sets the terminal as the timer output. Use this setting with the timer input set in H1-xx = 18 [MFDI Function Selection = Timer
Function].
Note:
Refer to Timer Function Operation on page 666 for more information.
13: Speed Agree 2
Setting Value Function Description
13 Speed Agree 2
The terminal activates when the output frequency is in the range of the frequency reference ± L4-04 [Speed Agree Detection
Width (+/-)].
Note:
The detection function operates in the two motor rotation directions.
The drive outputs the motor speed status when A1-02 = 3, 7 [Control Method Selection = CLV, CLV/PM].
ON : The output frequency is in the range of “frequency reference ± L4-04”.
OFF : The output frequency is not in the range of “frequency reference ± L4-04”.
Figure 12.98 Speed Agree 2 Time Chart
14: User-Set Speed Agree 2
Setting Value Function Description
14 User-Set Speed Agree 2
The terminal activates when the output frequency is in the range of L4-03 [Speed Agree Detection Level (+/-)] ± L4-04 [Speed
Agree Detection Width (+/-)] and in the range of the frequency reference ± L4-04.
Note:
The detection level set in L4-03 is a signed value. The drive will only detect in one direction.
The drive outputs the motor speed status when A1-02 = 3, 7 [Control Method Selection = CLV, CLV/PM].
ON : The output frequency is in the range of L4-03 ± L4-04 and the range of frequency
reference ± L4-04.
OFF : The output frequency is not in the range of L4-03 ± L4-04 or the range of frequency
reference ± L4-04.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV

Table of Contents

Related product manuals