Parameter Details
12
12.8 H: Terminal Functions
YASKAWA SIEPC71061705H GA700 Series Technical Manual 841
39: Watt Hour Pulse Output
Setting Value Function Description
39 Watt Hour Pulse Output
Outputs the pulse that shows the watt hours.
Note:
Refer to H2-06: Watt Hour Output Unit Selection for more information.
3C: LOCAL Control Selected
Setting Value Function Description
3C LOCAL Control Selected
The terminal activates when the Run command source or frequency reference source is LOCAL.
ON : LOCAL
The keypad is the Run command source or the frequency reference source.
OFF : REMOTE
The Run command source or frequency reference source is an external source set with b1-01 [Frequency
Reference Selection 1], b1-15 [Frequency Reference Selection 2], b1-02 [Run Command Selection 1], or b1-16
[Run Command Selection 2].
3D: During Speed Search
Setting Value Function Description
3D During Speed Search
The terminal activates when the drive is doing speed search.
Note:
Refer to b3: Speed Search for more information.
3E: PID Feedback Low
Setting Value Function Description
3E PID Feedback Low
The terminal activates when the drive detects FbL [PID Feedback Loss].
The drive detects FbL [PID Feedback Loss] when the PID feedback value < b5-13 [PID Feedback Loss Detection
Lvl] for longer than b5-14 [PID Feedback Loss Detection Time].
Note:
Refer to PID Feedback Loss Detection on page 670 for more information.
3F: PID Feedback High
Setting Value Function Description
3F PID Feedback High
The terminal activates when the drive detects FbH [Excessive PID Feedback].
The drive detects FbH [Excessive PID Feedback] when the PID feedback value > b5-36 [PID High Feedback
Detection Lvl] for longer than b5-37 [PID High Feedback Detection Time].
Note:
Refer to PID Feedback Loss Detection on page 670 for more information.
4A: During KEB Ride-Thru
Setting Value Function Description
4A During KEB Ride-Thru
The activates during KEB Ride-Thru.
Note:
Refer to KEB Ride-Thru Function on page 877 for more information.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV