3.4 Main Circuit Terminal Block Wiring Procedure
92 YASKAWA SIEPC71061705H GA700 Series Technical Manual
2. Remove the terminal block nut.
A - Nut
Figure 3.30 Remove the Terminal Block Nut
3. Wire the closed-loop crimp terminal to the main circuit terminal block.
Figure 3.31 Install the Electrical Wire
4. Tighten the nut to the specified torque.
Figure 3.32 Tighten the Terminal Block Nut
5. Examine the signal from the wired terminal and use a diagonal-cutting pliers to remove areas of the wiring
cover cutaway section.
Cut the areas shown in Figure 3.33.
A - Cutaway sections B - Use a diagonal-cutting pliers to clip this area.
Figure 3.33 Clip the Cutaway Section of the Wiring Cover