EasyManua.ls Logo

YASKAWA GA700 Series - Page 998

YASKAWA GA700 Series
1021 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Docu ment No. E ZZ024048<1>
Pr epared in October, 2021
14 / 19
First Row: Drive Information
This example shows the data text strings and data generated for the first row of log data.
Example of generated data for a long-term data log:
00,0012,160107111230,GA700,VSAA01010,2,62,1000,000001
Example of generated data for a short-term data log:
00,1012,160107111230,GA700,VSAA01010,2,62,10,1,1000,
1,E,102,50.0,1,50,5020,000001
No.
It e m
Nu mber of
Ch aracters
Ex ample
De scription
1
Attribute
2
00
[00] shows that the record is a drive information record.
2
File number
4
0012
Long-term data log: Shows the [xxx] part (a 3-digit number) of
the [GLOG0xxx.csv] filename.
Short-term data log: Shows the [xxx] part (a 3-digit number) of
the [SLOG0xxx.csv] filename + 1000.
3
Time stamp
*1
12
160107111230
Date file was generated
Date: 20YY/MM/DD
Time in 24-hour format: HH:MM:SS
Example data of [160107111230]: 11:12:30 on January 7,
2016
4
Model
5
GA700
Drive model information
5
Software
number
9
VSAA01010
Drive software number
6
Control
method
selection
1
2
Setting value (Dec.) of
A1-02 [Control Method Selection]
7
Drive capacity
2
62
Setting value (Hex.) of
o2-04 [Drive Model (KVA) Selection]
8
Sampling time
5
(maximum)
1000
Setting value (Dec.) of
o5-02 [Log Sampling Interval]
Unit: ms
9
Log data
type
*2
1
1
1: Short-term data log (trend log disabled)
2: Short-term log for short-term data log (trend log enabled)
3: Trend log for short-term data log (trend log enabled)
10
Trend log
sampling
cycle
*2
5
(Maximum)
1000
Sampling cycle (Dec.) selected by
o5-21 [Trend Log Sampling
Time Selection]
Unit: ms
11
Trigger type
*2
1
1
Setting value (Dec.) of
o5-15 [Trigger Type Selection]
12
Digital
trigger target
*2
2
(Maximum)
E
Setting value (Hex.) of
o5-16 [Digital Trigger Object]
13
Analog
trigger target
*2
3
102
Setting value (Dec.) of
o5-17 [Analog Trigger Object]
14
Analog
trigger level
*2
6
(Maximum)
50.0
Setting value (Dec.) of
o5-18 [Analog Trigger Level]
Unit: %
15
Trigger
condition
*2
1
1
Setting value (Dec.) of
o5-19 [Trigger Condition]
16
Pre-trigger
*2
3
(Maximum)
50
Setting value (Dec.) of
o5-20 [Pre-Trigger Setting]
Unit: %
17
Offset
between
data
*2
6
(Maximum)
5020
Time offset (Dec.) between the trend log and short-term log for
short-term data log (trend log enabled)
Unit: ms
18
Row number
6
000001
Row number (Hex.) in the data log file
*1 If you do not set the time in the keypad, the text string of [000000000000] is generated to show the time.
*2 Generated only for a short-term data log.

Table of Contents

Related product manuals