EasyManua.ls Logo

Allied Telesis AT-GS900M Series - Enable Switch Stormdetection

Allied Telesis AT-GS900M Series
542 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AT-GS900M Series CLI Reference
Section III: Layer 2 Switching 247
ENABLE SWITCH STORMDETECTION
Syntax
enable switch stormdetection port=
port_list
|all
Parameters
port_list
Specifies a list of ports. To specify multiple ports, use a comma (,)
to separate them. To specify a range of ports, use a hyphen (-).
all
Specifies all the switch ports.
Description
Use this command to enable detecting the receiving rate. By default,
detecting the receiving rate is disabled.
To enable detecting the receiving rate on a trunk port, you must specify all
trunk ports in the trunk group.
Confirmation Command
“SHOW SWITCH STORMDETECTION” on page 276
Example
The following command enables detecting the receiving rate:
Manager > enable switch stormdetection port=2