Chapter 16: Forwarding Database (FDB) Commands
298 Section III: Layer 2 Switching
SET SWITCH AGEINGTIMER
Syntax
set switch agingtimer=
time
Parameters
time
Specifies time in seconds that the dynamic entries in FDB are
expired. The range is 1 to 1,000,000 seconds. The default setting
is 300 seconds.
Description
Use this command to change timer for the dynamic entires in FDB to be
expired. A dynamic entry is deleted from FDB when any frame with the
destination MAC address of the dynamic entry has not been received for
the period of the specified time.
Confirmation Command
“SHOW SWITCH FDB” on page 299
Example
The following command changes the aging timer to 500 seconds:
Manager > set switch agingtimer=500