Chapter 18: Power Over Ethernet (PoE) Commands
342 Section III: Layer 2 Switching
SHOW POE
Syntax
show POE
Parameters
None
Description
Use this command to display information about PoE settings and ports. An
example of the command output is shown in Figure 52.
Figure 52. SHOW POE Command
Example
The following example displays information about PoE settings and ports:
Manager > show poe
PoE Global Power Status:
--------------------------------------------------
Power Management Mode ........ Actual
Power Detect Mode ............ IEEE
PoE Limit .................... 75 W
Guard Band ................... 10 W
PoE No Connect ............... 65 W
Total Allocated Power ........ 0 W
Consumed Power ............... 0 W
Available Power .............. 75 W
Consumed Power Usage ......... 0 percent
Consumed Power Threshold ..... 95 percent
PoE All Ports Power Status Summary:
Port PoE Status Class Consumed(mW) Power State
-----------------------------------------------------------------
1 Enabled - 0 OFF - Detection in process
2 Enabled - 0 OFF - Detection in process
3 Enabled - 0 OFF - Detection in process
4 Enabled - 0 OFF - Detection in process
-----------------------------------------------------------------

Table of Contents