Chapter 3: Basic CLI Management Commands
52 Section I: Getting Started
SET SYSTEM
Syntax
set system name=”
system_name
”|location=
location_name
”|
contact=”
contact_name
Parameter
system_name
Specifies a value for the sysName MIB object.
location_name
Specifies a value for the sysLocation MIB object.
contact_name
Specifies a value for the sysContact MIB object.
Description
Use this command to specify the values of MIB objects: sysName,
sysLocation, and sysContact:
Confirmation Command
“SHOW SYSTEM” on page 58
Example
The following command specifies the value of the sysName MIB object to
GS916MV2:
manager > set system name=”GS926MV2”
The following command deletes the value of the sysLocation MIB object:
Manager > set system loaction=””