Chapter 1: Cyclone IV Device Datasheet 1–15
Operating Conditions
December 2016 Altera Corporation Cyclone IV Device Handbook,
Volume 3
LVDS
(Column
I/Os)
2.375 2.5 2.625 100
0.05 D
MAX
500 Mbps 1.80
247 600 1.125 1.25 1.3750.55
500 Mbps D
MAX
700 Mbps
1.80
1.05 D
MAX
> 700 Mbps 1.55
BLVDS (Row
I/Os)
(4)
2.375 2.5 2.625 100
BLVDS
(Column
I/Os)
(4)
2.375 2.5 2.625 100
mini
-LVDS
(Row I/Os)
(5)
2.375 2.5 2.625 300 600 1.0 1.2 1.4
mini
-LVDS
(Column
I/Os)
(5)
2.375 2.5 2.625 300 600 1.0 1.2 1.4
RSDS
®
(Row
I/Os)
(5)
2.375 2.5 2.625 100 200 600 0.5 1.2 1.5
RSDS
(Column
I/Os)
(5)
2.375 2.5 2.625 100 200 600 0.5 1.2 1.5
PPDS
(Row
I/Os)
(5)
2.375 2.5 2.625 100 200 600 0.5 1.2 1.4
PPDS
(Column
I/Os)
(5)
2.375 2.5 2.625 100 200 600 0.5 1.2 1.4
Notes to Table 1–20:
(1) For an explanation of terms used in Table 1–20, refer to “Glossary” on page 1–37.
(2) V
IN
range: 0 V V
IN
1.85 V.
(3) R
L
range: 90 R
L
110 .
(4) There are no fixed V
IN
, V
OD
, and V
OS
specifications for BLVDS. They depend on the system topology.
(5) The Mini
-LVDS, RSDS, and PPDS standards are only supported at the output pins.
(6) The LVPECL I/O standard is only supported on dedicated clock input pins. This I/O standard is not supported for output pins.
Table 1–20. Differential I/O Standard Specifications for Cyclone IV Devices
(1)
(Part 2 of 2)
I/O Standard
V
CCIO
(V) V
ID
(mV) V
IcM
(V)
(2)
V
OD
(mV)
(3)
V
OS
(V)
(3)
Min Typ Max Min Max Min Condition Max Min Typ Max Min Typ Max

Table of Contents