10-44 Interface ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Variables V600 to V999 and the indexed Variables V500 to V519 are
cleared.
Format:
! s C C L V A R $ h h CR LF
Clear a variable range.
Format:
! s C C L V A R v v v v b b b b $ h h CR LF
vvvv = starting with variable number (0600...0999)
bbbb = up to and including variable number (0600...0999)
Clear system variables.
Format:
! s C C L V A R n n n n $ h h CR LF
nnnn = Number of the system variables
0019, 0020 and 0105 are allowable
Note: These commands are only accepted in Parameter Mode.
A Yes response follows, and the command is successfully completed.
All saved marker flags (M3, M6 and M8) are cleared.
Format:
! s C C L M _ _ $ h h CR LF
A particular group of saved NC marker flags is cleared.
Format:
! s C C L M _ _ m n $ h h CR LF
m = "M" for marker flag
n = Group number
The saved NC marker flags are groups M3, M6 M8.
Note: These commands are only accepted in Parameter Mode.
A Yes response follows, and the command is successfully completed.
Clear NC Variables:
Clear Saved Marker Flags: