EasyManua.ls Logo

ComAp InteliDrive DCU Marine - RHS Index; Lighttimeoff; Timer on

ComAp InteliDrive DCU Marine
285 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
InteliDrive DCU Marine - 3.0.0 Global Guide
115
Setpoint group Basic settings Related FW 3.0.0
Range [units] 1 .. 10 [-]
Default value 1
Step 1
Comm object 15794 Related applications All
Config level Standard
Setpoint visibility Always
Description
RHS Index (RHS means Running Hours Souce ) is index of ECU module, which is used as source of engine
running hours.
RHS Index
6 back to List of setpoints
Setpoint group Basic settings Related FW 3.0.0
Range [units] 0 .. 250 [min]
Default value 0
Step 1
Comm object 10121 Related applications All
Config level Standard
Setpoint visibility Always
Description
Timeout for ID display backlight automatic switch off. Zero setting disables display backlight switch off.
Backlight is automatically switched on after any key press or Alarm activation.
Note: LightTimerOff setpoint influences the Remote panel not master controller when changed on
Remote panel.
LightTimeOff
6 back to List of setpoints
Setpoint group Basic settings Related FW 3.0.0
Range [units] [hh:mm:ss]
Default value 0:00:00
Step [-]
Comm object 10042 Related applications All
Config level Standard
Setpoint visibility Always
Description
See Timer Repeat (page 116) description.
Timer ON
6 back to List of setpoints

Table of Contents

Other manuals for ComAp InteliDrive DCU Marine

Related product manuals