Setpoint group Engine protect Related FW 3.0.0
Range [units] 0 .. 60 [s]
Default value 0
Step 1
Comm object 10569 Related applications All
Config level Standard
Setpoint visibility Always
Description
Delay for Force block protection activation after binary input Force Block 1 is opened. Protection
deactivation is without delay. Protection is activated/deactivated independent on engine running or not
running state.
ForceBlockDel1
6 back to List of setpoints
Setpoint group Engine protect Related FW 3.0.0
Range [units] 0 .. 60 [s]
Default value 0
Step 1
Comm object 10570 Related applications All
Config level Standard
Setpoint visibility Always
Description
Delay for Force block protection activation after binary input Force Block 2 is opened. Protection
deactivation is without delay. Protection is activated/deactivated independent on engine running or not
running state.
ForceBlockDel2
6 back to List of setpoints

Table of Contents

Other manuals for ComAp InteliDrive DCU Marine

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ComAp InteliDrive DCU Marine and is the answer not in the manual?

ComAp InteliDrive DCU Marine Specifications

General IconGeneral
BrandComAp
ModelInteliDrive DCU Marine
CategoryController
LanguageEnglish

Related product manuals