EasyManuals Logo

ComAp InteliDrive DCU Marine User Manual

ComAp InteliDrive DCU Marine
285 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #130 background imageLoading...
Page #130 background image
InteliDrive DCU Marine - 3.0.0 Global Guide
130
Setpoint group Engine params Related FW 3.0.0
Range [units] [ENABLED, CHRGFAIL, DISABLED]
Default value DISABLED
Step [-]
Comm object 9683 Related applications All
Config level Standard
Setpoint visibility Always
Description
ENABLED: The D+ terminal is used for both functions “running engine detection and charge fail
detection.
CHRGFAIL: The D+ terminal is used for charge fail detection only
DISABLED: The D+ terminal is not used.
Note: Alternator magnetization current is provided independently from the parameter setting.
D+ function
6 back to List of setpoints

Table of Contents

Other manuals for ComAp InteliDrive DCU Marine

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ComAp InteliDrive DCU Marine and is the answer not in the manual?

ComAp InteliDrive DCU Marine Specifications

General IconGeneral
BrandComAp
ModelInteliDrive DCU Marine
CategoryController
LanguageEnglish

Related product manuals