130
Setpoint group Engine params Related FW 3.0.0
Range [units] [ENABLED, CHRGFAIL, DISABLED]
Default value DISABLED
Step [-]
Comm object 9683 Related applications All
Config level Standard
Setpoint visibility Always
Description
ENABLED: The D+ terminal is used for both functions “running engine detection and charge fail
detection.
CHRGFAIL: The D+ terminal is used for charge fail detection only
DISABLED: The D+ terminal is not used.
Note: Alternator magnetization current is provided independently from the parameter setting.
D+ function