InteliDrive DCU Marine - 3.0.0 Global Guide
221
Related FW 3.0.0 Related applications RPU
Comm object 10213
Description
Binary output Stop solenoid (SS) status when output is opened – see FS-Load (page 220)
FS / SS -Status FS / SS -Load
FS / SS is closed, normal operation 1 No meaning
FS / SS is closed, HC or OT 0 No meaning
FS / SS is opened, normal operation No meaning 0
FS / SS is opened, BW No meaning 1
SS-Load
6 back to List of LBO
Related FW 3.0.0 Related applications RPU
Comm object 10213
Description
Status of ID-RPU Fuel solenoid and Stop solenoid power supply terminal. Active when Power supply is
NOT connected.
BinOut Power
6 back to List of LBO
Related FW 3.0.0 Related applications RPU
Comm object 10213
Description
Indicates that system is switched to Battery B.
Battery Fail
6 back to List of LBO
Related FW 3.0.0 Related applications RPU
Comm object 10213
Description
When closed ID-RPU module is active (after ID-DCU MARINE fail) for engine Sd and Overspeed
protection.
RPU control
6 back to List of LBO