InteliDrive DCU Marine - 3.0.0 Global Guide
128
Setpoint group Engine params Related FW 3.0.0
Range [units] 0 .. 600 [s]
Default value 0
Step 1
Comm object 8780 Related applications All
Config level Standard
Setpoint visibility Always
Description
This is the time the binary output Prelubrication is active. The controller will activate binary output
Prelubrication for this amount of time, then pause for PrelubrPause, then activate again. This will continue
the entire time the engine is not running. Function is not active in controller OFF mode.
PrelubrTime
6 back to List of setpoints
Setpoint group Engine params Related FW 3.0.0
Range [units] 1 .. 4000 [min]
Default value 1
Step 1
Comm object 8781 Related applications All
Config level Standard
Setpoint visibility Always
Description
Time interval between prelubrication cycles PrelubrTime (page 128).
Note: To use Prelubrication, configure Binary output Prelubrication at first.
Prelubrication is disabled in controller OFF mode or when PrelubrTime is set to zero.
When engine is running Prelubrication binary output is opened.
Prelubrication starts PrelubrPause after engine stops. Prelubrication starts immediately when:
- controller power supply turns on
- mode changes from OFF to another
- Emergency Stop is released
PrelubrPause
6 back to List of setpoints