InteliDrive DCU Marine - 3.0.0 Global Guide
201
Related FW 3.0.0 Related applications All
Comm object 6
Description
The output closes when any Sensor fail alarm is active. Output opens when all Fls alarms disappear and
Fault reset is pressed (no Fls alarm in Alarm list).
Common Fls
6 back to List of LBO
Related FW 3.0.0 Related applications All
Comm object 1942
Description
Provides feedback information that command (LBI function) REGENINHIBIT (PAGE 217) is active
CMD RegInhOn
6 back to List of LBO
Related FW 3.0.0 Related applications All
Comm object 17
Description
TThe output is closed in controller OFF mode.
OFF Mode
6 back to List of LBO
Related FW 3.0.0 Related applications All
Comm object 1831
Description
Active signal indicates that DPF (Diesel Particulate Filter) is starting to overfill with soot because the
system is unable to undertake an automatic active regeneration. It starts flashing when the DPF is nearly
full, engine power may be reduced.
DPF Lamp
6 back to List of LBO
Related FW 3.0.0 Related applications PRP, AUX, HRB
Comm object 9887
Description
PRP Mode (PRP only) The output is closed in controller PRP mode.
AUXMode (AUX only) The output is closed in controller AUX mode.
HRB Mode (CMB only) The output is closed in controller HRB mode.
Controller mode
6 back to List of LBO