InteliDrive DCU Marine - 3.0.0 Global Guide
202
Related FW 3.0.0 Related applications All
Comm object 258
Description
The output is closed, if LOC (Local) mode is not selected.
Not In LOC
6 back to List of LBO
Related FW 3.0.0 Related applications All
Comm object 259
Description
The output is closed, if LOC (Local) mode is selected.
In LOC
6 back to List of LBO
Related FW 3.0.0 Related applications All
Comm object 260
Description
CPU indication output is closed when CPU is ready.
CPU Ready
6 back to List of LBO
Related FW 3.0.0 Related applications PRP
Comm object 261
Description
Output is closed if Binary input Rem Clutch is active or controller front panel I/0 button is pressed and actual
engine RPM is between: ClutchMinSpeed and ClutchMaxSpeed.
Output stays closed even if the RPM goes out of limits above. Can’t be opened by button when Binary input
Rem Clutch is closed. BI Rem clutch is not active in LOC (Local) mode.
Clutch Connect (PRP only)
6 back to List of LBO

Table of Contents

Other manuals for ComAp InteliDrive DCU Marine

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ComAp InteliDrive DCU Marine and is the answer not in the manual?

ComAp InteliDrive DCU Marine Specifications

General IconGeneral
BrandComAp
ModelInteliDrive DCU Marine
CategoryController
LanguageEnglish

Related product manuals