InteliDrive DCU Marine - 3.0.0 Global Guide
156
Setpoint group Load sharing Related FW 3.0.0
Range [units] 0,0 .. 100,0 [%]
Default value 50,0
Step 0,1
Comm object 10099 Related applications PRP
Config level Standard
Setpoint visibility Always
Description
See Load sharing block diagram (page 151) - the setpoint value is used instead of Engine Values: Speed
Request in loadsharing state, if Binary input Back Up Speed is active and LAI: Requested RPM reading via
analog input is out of range (sensor fail is detected).
Back Up Speed
6 back to List of setpoints
Setpoint group Load sharing Related FW 3.0.0
Range [units] 0 .. 600 [s]
Default value 60
Step 1
Comm object 10102 Related applications PRP
Config level Standard
Setpoint visibility Always
Description
Engine clutch start protection. Start fail alarm is activated, if engine running condition is not detected during
MaxClStrPer delay time after Binary output Clutch Connect is closed.
MaxClStrtPer
6 back to List of setpoints