EasyManua.ls Logo

ComAp InteliDrive DCU Marine - Batt < V; Batt Volt del; Overloadsplim

ComAp InteliDrive DCU Marine
285 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
InteliDrive DCU Marine - 3.0.0 Global Guide
142
Setpoint group Engine protect Related FW 3.0.0
Range [units] 8,0 .. Batt >V [V]
Default value 8,0
Step 0,1
Comm object 8387 Related applications All
Config level Standard
Setpoint visibility Always
Description
Warning level for low battery voltage.
Batt < V
6 back to List of setpoints
Setpoint group Engine protect Related FW 3.0.0
Range [units] 0 .. 600 [s]
Default value 10
Step 1
Comm object 8383 Related applications All
Config level Standard
Setpoint visibility Always
Description
Delay for battery voltage alarms.
Batt Volt Del
6 back to List of setpoints
Setpoint group Engine protect Related FW 3.0.0
Range [units] 0,0 .. 100,0 [%]
Default value 20,0
Step 0,1
Comm object 9950 Related applications PRP
Config level Standard
Setpoint visibility Always
Description
Engine overload protection limit. See Requested RPM, Overload protection (PRP only) (page 27)
OverloadSpLim
6 back to List of setpoints