205
Related FW 3.0.0 Related applications All
Comm object 263
Description
It activates when RPM rises above Starting RPM and opens when RPM=0.
Engine Running
6 back to List of LBO
Related FW 3.0.0 Related applications All
Comm object 37
Description
Ignition system activation/deactivation during start - stop procedure.
The output becomes active during cranking if RPM > 30, becomes inactive during cranking pause and after
stop of the engine (RPM = 0).
Ignition
6 back to List of LBO
Related FW 3.0.0 Related applications All
Comm object 264
Description
1 sec (fix) pulse prior to transfer from Running to Cooling state.
Unload
6 back to List of LBO
Related FW 3.0.0 Related applications All
Comm object 74
Description
Closes in cooling state, opens after engine stop.
Cooling
6 back to List of LBO
Related FW 3.0.0 Related applications All
Comm object 22
Description
Closed output opens the fuel solenoid. Adjustable to DIESEL or GAS. See also the Fuel Solenoid (page
131) setpoint description.
Fuel Solenoid
6 back to List of LBO